{"product_id":"the-extractor-twin-premium-dual-12v-powered-canopy-vent","title":"The Extractor Twin — Premium Dual 12V Powered Canopy Vent","description":"\u003cp\u003e\u003cstrong\u003eTwo fans, one serviceable filter, no shortcuts.\u003c\/strong\u003e The Extractor Twin\u003csup style=\"font-size:0.5em;line-height:0\"\u003e™\u003c\/sup\u003e puts a pair of IP67-rated Noctua industrial fans into a single glass fibre reinforced housing, giving large canopies, vans and caravans the airflow of two premium fans together with the easy-service filter that made \u003cem\u003e\u003cstrong\u003e\u003ca title=\"The Extractor\" href=\"https:\/\/ventit3d.au\/products\/the-extractor-premium-120mm-12v-canopy-vent\"\u003eThe Extractor\u003csup style=\"font-size:0.5em;line-height:0\"\u003e™\u003c\/sup\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e our top-end vent.\u003c\/p\u003e\n\u003cp\u003eWhere a single fan starts to struggle — long trays, high-roof canopies, caravan boots packed with a fridge, batteries and gear — the Twin moves twice the fan capacity through one clean, sealed install.\u003c\/p\u003e\n\u003cp\u003eLike every powered Ventit3D\u003csup style=\"font-size:0.5em;line-height:0\"\u003e™\u003c\/sup\u003e vent, the Twin is designed to exhaust. Give it an intake low on the opposite side — \u003cem\u003e\u003cstrong\u003e\u003ca title=\"The Original\" href=\"https:\/\/ventit3d.au\/products\/asa-carbon-fibre-filtered-canopy-vents\"\u003eThe Original\u003csup style=\"font-size:0.5em;line-height:0\"\u003e™\u003c\/sup\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e works well — and the two together set up a steady cross-flow through the whole space.\u003c\/p\u003e\n\u003ch3\u003eWhat makes the Twin premium\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo industrial Noctua fans\u003c\/strong\u003e — a matched pair of NF-F12 industrialPPC-2000 IP67 fans, each rated at 2000 RPM and 121.8 m³\/h, with Noctua's MTTF rating of more than 150,000 hours. Sealed against water and dust and built for continuous duty\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne big, washable filter\u003c\/strong\u003e — a single 10 mm, 45 PPI Unifilter polyurethane foam spans both fans and is clamped on every side, so dust has nowhere to slip past. Rinse it out or swap it for a new one\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless where it matters\u003c\/strong\u003e — two stainless steel fan guards and stainless fixings throughout, for salt air, wet seasons and years of use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-bolt filter access\u003c\/strong\u003e — release four M6 cap heads, lift the hinged fan box, service the foam and close it again. The vent itself never leaves the panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt heavier\u003c\/strong\u003e — thicker walls, denser infill and a wider print nozzle for stronger layer bonding across the larger housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAt a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree settings\u003c\/strong\u003e — run constantly, let the adjustable thermostat decide, or switch off to save battery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlugs straight in\u003c\/strong\u003e — 5.5 x 2.1 mm DC jack, with a right-angle connector in the box\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlim outside\u003c\/strong\u003e — the outer housing stands just 42 mm off the panel at its tallest and tapers toward the top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLouvres angled down\u003c\/strong\u003e to shed rain and road dust instead of catching it\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003e\u003ca title=\"Materials Guide ASA-GF\" href=\"https:\/\/ventit3d.au\/pages\/materials\"\u003e\u003cstrong\u003eASA-Glass Fibre\u003c\/strong\u003e\u003c\/a\u003e\u003c\/em\u003e outside for UV and heat resistance, ABS-Glass Fibre fan box inside for toughness\u003c\/li\u003e\n\u003cli\u003eBlack only for now\u003c\/li\u003e\n\u003cli\u003eDesigned and made in Australia, shipped free Australia-wide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInside the Twin\u003c\/h3\u003e\n\u003cp\u003eThree parts make up the Twin. On the outside, a low louvred housing. Through the panel, the Inner to Outer Vent Mount, which bolts to the outer housing and seals the opening. Inside, the fan box: both Noctua fans sit side by side behind their stainless guards, with the controller tucked away in its own compartment under a snap-fit lid.\u003c\/p\u003e\n\u003cp\u003eAir is pulled from the canopy, through the foam, across both fans and out through the downward louvres. When the fans stop, the foam stays put as a barrier against fine dust.\u003c\/p\u003e\n\u003cp\u003eA hinge along the top of the mount locates the fan box, and four M6 cap head bolts pull it down tight, squeezing the filter evenly around its edge.\u003c\/p\u003e\n\u003cp\u003eChoose always on, temperature activated or off on the built-in switch. In temperature mode the thermostat starts both fans as the space heats up and stops them again as it cools.\u003c\/p\u003e\n\u003ch3\u003eIs the Twin right for your build?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBig spaces\u003c\/strong\u003e — dual-cab canopies with high lids, van fit-outs, caravan front boxes and storage tunnels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-heavy loads\u003c\/strong\u003e — fridges, lithium batteries, inverters and DC-DC chargers all adding heat at once\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDusty country\u003c\/strong\u003e — corrugations and bulldust, where a filter you can actually service is worth having\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarsh climates\u003c\/strong\u003e — coastal, tropical or inland heat, where IP67 fans and stainless parts last longer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRunning a standard-size canopy? The single-fan \u003cem\u003e\u003cstrong\u003e\u003ca title=\"The Extractor\" href=\"https:\/\/ventit3d.au\/products\/the-extractor-premium-120mm-12v-canopy-vent\"\u003eExtractor\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e is usually all you need.\u003c\/p\u003e\n\u003ch3\u003eTwin, Extractor or Dual 120mm?\u003c\/h3\u003e\n\u003cp\u003eAll three are 12V powered exhaust vents. Here's how they line up.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eThe Extractor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eThe Extractor Twin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca title=\"Dual 120mm 12volt\" href=\"https:\/\/ventit3d.au\/products\/dual-120mm-12volt-canopy-air-vent\"\u003eDual 120mm\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFans\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x Noctua IP67\u003c\/td\u003e\n\u003ctd\u003e2 x Noctua IP67\u003c\/td\u003e\n\u003ctd\u003e2 x standard 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReplaceable 10 mm Uni foam\u003c\/td\u003e\n\u003ctd\u003eReplaceable 10 mm Uni foam, one large filter\u003c\/td\u003e\n\u003ctd\u003eBuilt-in filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlways on \/ temperature \/ off\u003c\/td\u003e\n\u003ctd\u003eAlways on \/ temperature \/ off\u003c\/td\u003e\n\u003ctd\u003eAlways on \/ variable-speed temperature \/ fixed 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCutout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 120 mm, R37 corners\u003c\/td\u003e\n\u003ctd\u003e2 x 120 x 120 mm side by side, R37 corners\u003c\/td\u003e\n\u003ctd\u003e2 x 105–108 mm round\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard canopies that work hard\u003c\/td\u003e\n\u003ctd\u003eLarge canopies, vans and caravans\u003c\/td\u003e\n\u003ctd\u003eLarge builds wanting variable fan speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVentit3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePremium dual-fan filtered 12V exhaust vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFans\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x Noctua NF-F12 industrialPPC-2000 IP67 PWM, 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e121.8 m³\/h per fan (fan only, free air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatic pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.94 mm H₂O per fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan rated life (MTTF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMore than 150,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne Unifilter 10 mm polyurethane foam, 45 PPI, washable and replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan guards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASA-Glass Fibre outer housing, ABS-Glass Fibre inner fan box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 x 2.1 mm DC jack, right-angle connector supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-way switch — always on \/ temperature activated (adjustable) \/ off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter housing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e284 mm wide x 226 mm long x 42 mm high from the panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner to Outer Vent Mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e274.8 mm wide x 224.5 mm long x 24 mm thick overall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth inside the canopy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbout 56 mm from the inside of the canopy wall to the top of the installed fan box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain cutout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 120 x 120 mm openings side by side with R37 corners. Cut each with a 114 mm hole saw, then trim the corners to the template\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel fixing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 x M5 stainless button head bolts through 8 x 5 mm drilled holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan box fixing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x M6 stainless cap head bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack only for now\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 1,440 g, including the outer vent, Inner to Outer Vent Mount, fan box, bolts and circuitry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLouvres\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDownward facing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge 4x4 canopies, vans, caravans, camper trailers, trailers, structures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0915\/5097\/4236\/files\/the-extractor-twin-outer-housing.png\" alt=\"Ventit3D The Extractor Twin premium dual 12V powered canopy vent outer housing dimension diagram - 284 x 226 x 42 mm, 2 x 120 x 120 mm R37 cutouts\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0915\/5097\/4236\/files\/the-extractor-twin-inner-housing.png\" alt=\"Ventit3D The Extractor Twin premium dual 12V powered canopy vent inner housing dimension diagram - 275 x 225 mm, 56 mm installed depth inside the canopy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eIn the box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFan box with both Noctua IP67 fans, stainless guards, three-way switch and thermostat fitted\u003c\/li\u003e\n\u003cli\u003eInner to Outer Vent Mount, with built-in hinge\u003c\/li\u003e\n\u003cli\u003eLouvred outer vent housing\u003c\/li\u003e\n\u003cli\u003e10 mm Uni foam filter, cut to size\u003c\/li\u003e\n\u003cli\u003eRight-angle DC power connector\u003c\/li\u003e\n\u003cli\u003e8 x M5 stainless button head bolts for the panel\u003c\/li\u003e\n\u003cli\u003e4 x M6 stainless cap head bolts for the fan box\u003c\/li\u003e\n\u003cli\u003e2 x 1:1 drilling templates — Inner Mount (recommended) and Outer Vent\u003c\/li\u003e\n\u003cli\u003eInstallation and filter change guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFitting the Twin\u003c\/h3\u003e\n\u003cp\u003eStart with the \u003cstrong\u003eInner Mount\u003c\/strong\u003e template on the \u003cstrong\u003einside\u003c\/strong\u003e of the panel — it lets you see frame rails and bracing before you drill. Prefer to work from outside? The Outer Vent template marks exactly the same holes. Drill the eight 5 mm holes, then cut the two main openings: a 114 mm hole saw for each, then trim the corners out to the 120 x 120 mm R37 shape marked on the template.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eRun sealant around the mating face of the outer housing.\u003c\/li\u003e\n\u003cli\u003eOffer the outer housing up to the outside of the panel with the \u003cstrong\u003elouvres pointing down\u003c\/strong\u003e. Fitted upside down, it will let water in.\u003c\/li\u003e\n\u003cli\u003eInside, run a bead of sealant around the opening on the panel face of the Inner to Outer Vent Mount and dab each bolt hole, then pull the mount and outer housing together with the eight M5 button heads.\u003c\/li\u003e\n\u003cli\u003eSeat the filter.\u003c\/li\u003e\n\u003cli\u003eHook the fan box onto the hinge at a slight angle, swing it down and fasten the four M6 cap heads — snug, not overtight. A drop of low-strength Loctite helps.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eConnect 12V through the DC jack and protect the circuit with a 5 A fuse, as you would any canopy accessory. Full instructions come in the box.\u003c\/p\u003e\n\u003ch3\u003eServicing the filter\u003c\/h3\u003e\n\u003cp\u003eFour bolts and you're in. Remove the M6 cap heads, swing the fan box up on its hinge, then wash the foam or fit a new one. Close it up, refit the bolts and you're done — the seal on the panel is never disturbed.\u003c\/p\u003e\n\u003cp\u003eCheck it more often after dusty trips. Replacement Uni filters are coming soon.\u003c\/p\u003e\n\u003ch3\u003ePairs well with\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"The Original\" href=\"https:\/\/ventit3d.au\/products\/asa-carbon-fibre-filtered-canopy-vents\"\u003e\u003cem\u003e\u003cstrong\u003eThe Original\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e — passive intake pair that completes the cross-flow\u003c\/li\u003e\n\u003cli\u003eReplacement Uni filter (coming soon) — a spare for long trips\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/ventit3d.au\/products\/dual-10mm-cable-inlet\"\u003e\u003cem\u003e\u003cstrong\u003eDual Cable Inlet\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e — sealed entry point for the 12V feed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant to note\u003c\/h3\u003e\n\u003cp\u003eIP67 is Noctua's rating for the fans, not a rating for the complete vent, which has not been independently tested. Any opening cut into a canopy, caravan or structure can leak if it is not installed and sealed correctly, is submerged, or is hit with high-pressure water such as a pressure washer or car wash. Correct installation, sealing and regular checks for wear, damage and seal condition are the installer's responsibility.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the Twin different from The Extractor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Twin carries two Noctua IP67 fans instead of one, in a larger housing with one larger Uni filter, and its fan box is held by four M6 bolts rather than two. The fans, stainless guards, three-way control and materials are the same.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I choose the Twin or the Dual 120mm?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose the Twin for industrial IP67 fans, stainless steel guards and a filter you can wash or replace in minutes. Choose the Dual 120mm if you want variable fan speed and a fixed 30°C trigger with standard fans.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the Twin move twice as much air as The Extractor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt has twice the fan capacity — two of the same Noctua fans, each rated at 121.8 m³\/h in free air. Real-world airflow depends on the filter, your intake and the space, but the Twin will turn over a large canopy, van or caravan much faster than a single fan.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Twin IP67 rated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe fans are — Noctua rates them IP67 for water and dust. The complete vent has not been independently tested, so careful installation and sealing still matter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I service the filter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRemove the four M6 cap heads, tilt the fan box up on its hinge, and wash or replace the foam. How often depends on your conditions — dusty roads mean more frequent checks. Replacement filters are coming soon.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat fuse does the Twin need?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA 5 A fuse, the same as The Extractor. As with any 12V accessory in a canopy or caravan, always fuse the circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the Twin need a bigger hole than The Extractor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The Twin needs two of The Extractor's 120 x 120 mm R37 openings side by side, each started with a 114 mm hole saw and trimmed at the corners, plus eight 5 mm fixing holes instead of seven. Both 1:1 drilling templates are supplied in the box.\u003c\/p\u003e","brand":"Ventit3D","offers":[{"title":"Black","offer_id":54773538259228,"sku":"Extract-02","price":433.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/5097\/4236\/files\/The-Extractor-Twin-12V-Filtered-Canopy-Vent-01_90e61d8a-77e1-4836-ad5f-df9ba13ec9c2.jpg?v=1793083004","url":"https:\/\/ventit3d.au\/products\/the-extractor-twin-premium-dual-12v-powered-canopy-vent","provider":"Ventit3D","version":"1.0","type":"link"}